    "uuid": "c8124e46a18b4dd38e13d7d89ffb7468",
    "elementtype": "fichinter",
    "schema_kind": "intervention",
    "title": "Fiche d'intervention - Vérification volets coupe-feu sur conduits",
    "description": "Vérification des volets coupe-feu sur conduits aérauliques : déclenchement, fusible thermique, étanchéité",
    "export_date": "2026-05-26 10:00:00",
    "dolibarr_version": "18.0.0",
    "extrafields": [
        {
            "name": "vcf_etablissement",
            "label": "Établissement",
            "type": "varchar",
            "size": "200",
            "required": 1,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Nom et adresse",
            "pos": 100,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "vcf_localisation",
            "label": "Localisation du volet",
            "type": "varchar",
            "size": "150",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Conduit / niveau / zone",
            "pos": 110,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "vcf_reference",
            "label": "Référence / identifiant",
            "type": "varchar",
            "size": "100",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Repérage installation",
            "pos": 120,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "vcf_marque",
            "label": "Marque / modèle",
            "type": "varchar",
            "size": "100",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Fabricant",
            "pos": 130,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "vcf_classement",
            "label": "Classement coupe-feu",
            "type": "select",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": {
                "options": {
                    "ei30": "EI 30",
                    "ei60": "EI 60",
                    "ei90": "EI 90",
                    "ei120": "EI 120",
                    "ei240": "EI 240"
                }
            },
            "help": "Degré coupe-feu",
            "pos": 140,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "ei60",
            "alwayseditable": 0
        },
        {
            "name": "vcf_temp_declenchement",
            "label": "Température déclenchement (°C)",
            "type": "int",
            "size": "4",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Fusible thermique - typiquement 72 °C",
            "pos": 150,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "type_intervention",
            "label": "Type d'intervention",
            "type": "select",
            "size": "",
            "required": 1,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": {
                "options": {
                    "annuelle": "Vérification annuelle",
                    "reception": "Réception avant mise en service",
                    "apres_travaux": "Après travaux",
                    "corrective": "Maintenance corrective"
                }
            },
            "help": "Nature de l'intervention",
            "pos": 200,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "annuelle",
            "alwayseditable": 0
        },
        {
            "name": "verif_acces_trappe",
            "label": "Trappe de visite accessible",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Manoeuvre possible",
            "pos": 300,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "verif_fusible_thermique",
            "label": "Fusible thermique en place",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Pastille intacte",
            "pos": 310,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "verif_ressort_armement",
            "label": "Ressort / mécanisme d'armement OK",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Tension correcte",
            "pos": 320,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "verif_test_declenchement",
            "label": "Essai de déclenchement réussi",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Fermeture complète",
            "pos": 330,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "verif_fin_de_course",
            "label": "Contact fin de course OK",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Signalement SSI",
            "pos": 340,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "verif_etancheite_volet",
            "label": "Étanchéité en position fermée",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Pas de passage d'air",
            "pos": 350,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "verif_etat_lame",
            "label": "État des lames OK",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Pas de déformation ni corrosion",
            "pos": 360,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "verif_calfeutrement",
            "label": "Calfeutrement passage paroi OK",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Résine, mortier, mousse coupe-feu",
            "pos": 370,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "verif_etiquetage",
            "label": "Étiquetage / repérage présent",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Identifiable et lisible",
            "pos": 380,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "verif_reearmement",
            "label": "Réarmement après essai effectué",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Position normale de service",
            "pos": 390,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "anomalies_constatees",
            "label": "Anomalies constatées",
            "type": "text",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 0,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Description des défauts",
            "pos": 500,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "mesures_correctives",
            "label": "Mesures correctives",
            "type": "text",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 0,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Actions réalisées",
            "pos": 510,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "conclusion",
            "label": "Conclusion",
            "type": "select",
            "size": "",
            "required": 1,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": {
                "options": {
                    "apte": "APTE à l'utilisation",
                    "apte_reserve": "APTE avec réserves mineures",
                    "inapte": "INAPTE - Intervention urgente"
                }
            },
            "help": "Résultat de la vérification",
            "pos": 600,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "apte",
            "alwayseditable": 0
        },
        {
            "name": "date_prochaine_verif",
            "label": "Date prochaine vérification",
            "type": "date",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Périodicité annuelle réglementaire",
            "pos": 610,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "technicien_nom",
            "label": "Nom du vérificateur",
            "type": "varchar",
            "size": "100",
            "required": 1,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Personne compétente",
            "pos": 700,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "qualification",
            "label": "Qualification / société",
            "type": "varchar",
            "size": "100",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "APSAD F4, organisme agréé",
            "pos": 710,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        }
    ],
    "pdf_layout": {
        "version": "1.0",
        "page": {
            "format": "A4",
            "orientation": "portrait",
            "margins": { "top": 20, "right": 15, "bottom": 20, "left": 15 },
            "font_family": "helvetica",
            "font_size": 10
        },
        "header": {
            "title": "Vérification volet coupe-feu sur conduit",
            "subtitle": "Conduits aérauliques - déclenchement et étanchéité",
            "logo_placeholder": "top-right",
            "show_page_number": true,
            "show_generated_date": true
        },
        "footer": {
            "text": "Document généré via schemas.cap-rel.fr",
            "legal_mentions": "Document à conserver selon la réglementation en vigueur"
        },
        "sections": [
            {
                "id": "identification",
                "title": "Identification du volet",
                "layout": "two_columns",
                "fields": [
                    "vcf_etablissement",
                    "vcf_localisation",
                    "vcf_reference",
                    "vcf_marque",
                    "vcf_classement",
                    "vcf_temp_declenchement"
                ]
            },
            {
                "id": "intervention",
                "title": "Type d'intervention",
                "layout": "single_column",
                "fields": ["type_intervention"]
            },
            {
                "id": "mecanique",
                "title": "Mécanisme",
                "layout": "checklist",
                "fields": [
                    "verif_acces_trappe",
                    "verif_fusible_thermique",
                    "verif_ressort_armement"
                ]
            },
            {
                "id": "essai",
                "title": "Essai de déclenchement",
                "layout": "checklist",
                "fields": [
                    "verif_test_declenchement",
                    "verif_fin_de_course",
                    "verif_reearmement"
                ]
            },
            {
                "id": "etat",
                "title": "État et intégrité",
                "layout": "checklist",
                "fields": [
                    "verif_etancheite_volet",
                    "verif_etat_lame",
                    "verif_calfeutrement",
                    "verif_etiquetage"
                ]
            },
            {
                "id": "observations",
                "title": "Anomalies et mesures correctives",
                "layout": "full_width",
                "fields": [
                    "anomalies_constatees",
                    "mesures_correctives"
                ]
            },
            {
                "id": "conclusion",
                "title": "Conclusion de la vérification",
                "layout": "highlight_box",
                "fields": ["conclusion", "date_prochaine_verif"]
            },
            {
                "id": "signatures",
                "title": "Vérificateur",
                "layout": "signature_block",
                "fields": ["technicien_nom", "qualification"],
                "signature_boxes": [
                    { "label": "Signature vérificateur", "for_field": "technicien_nom" },
                    { "label": "Signature exploitant", "for_field": null }
                ]
            }
        ],
        "field_render": {
            "vcf_etablissement": { "style": "bold" },
            "conclusion": {
                "style": "highlight",
                "color_by_value": {
                    "apte": "#1f8a1f",
                    "apte_reserve": "#e69500",
                    "inapte": "#c00000"
                }
            },
            "anomalies_constatees": { "min_height": 30, "show_if_empty": false },
            "mesures_correctives": { "min_height": 30, "show_if_empty": false },
            "vcf_temp_declenchement": { "suffix": " °C" }
        }
    }
}