    "uuid": "bcbcf56e107d564d2f70cb003426d4cf",
    "elementtype": "fichinter",
    "schema_kind": "intervention",
    "title": "Vérification SSI (Système de Sécurité Incendie)",
    "description": "Fiche de vérification périodique et maintenance des Systèmes de Sécurité Incendie selon norme NF S 61-933 et règlement ERP MS 72-75",
    "export_date": "2024-12-04 16:30:00",
    "dolibarr_version": "18.0.0",
    "extrafields": [
        {
            "name": "ssi_etablissement",
            "label": "Établissement",
            "type": "varchar",
            "size": "200",
            "required": 1,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Nom et adresse de l'établissement",
            "pos": 100,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "ssi_type_erp",
            "label": "Type ERP",
            "type": "varchar",
            "size": "50",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Type et catégorie ERP (ex: L 4ème cat)",
            "pos": 110,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "ssi_categorie",
            "label": "Catégorie SSI",
            "type": "select",
            "size": "",
            "required": 1,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": {
                "options": {
                    "cat_a": "Catégorie A - SSI complet",
                    "cat_b": "Catégorie B - SDI + SMSI",
                    "cat_c": "Catégorie C - SDI seul",
                    "cat_d": "Catégorie D - Équipement alarme type 3",
                    "cat_e": "Catégorie E - Équipement alarme type 4"
                }
            },
            "help": "Catégorie du SSI selon MS 53",
            "pos": 120,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "type_intervention",
            "label": "Type d'intervention",
            "type": "select",
            "size": "",
            "required": 1,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": {
                "options": {
                    "verification_annuelle": "Vérification périodique annuelle",
                    "verification_triennale": "Vérification réglementaire triennale (VRE)",
                    "maintenance_preventive": "Maintenance préventive",
                    "maintenance_corrective": "Maintenance corrective",
                    "mise_en_service": "Mise en service initiale"
                }
            },
            "help": "Nature de l'intervention selon réglementation",
            "pos": 200,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "verification_annuelle",
            "alwayseditable": 0
        },
        {
            "name": "verif_dossier_identite",
            "label": "Dossier d'identité SSI conforme",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Présence et conformité du dossier d'identité",
            "pos": 300,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "verif_autocontrole",
            "label": "Fiches d'autocontrôle à jour",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Vérification hebdomadaire par l'exploitant",
            "pos": 310,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "verif_contrat_maintenance",
            "label": "Contrat de maintenance actif",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Présence contrat maintenance (obligatoire cat A et B)",
            "pos": 320,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "essai_cmsi",
            "label": "CMSI - Essai fonctionnel",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Centralisateur de Mise en Sécurité Incendie",
            "pos": 400,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "essai_detecteurs",
            "label": "Détecteurs automatiques OK",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Essai fonctionnel de chaque détecteur automatique",
            "pos": 410,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "nb_detecteurs_testes",
            "label": "Nombre détecteurs testés",
            "type": "int",
            "size": "4",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 1,
            "printable": 1,
            "param": [],
            "help": "Nombre de détecteurs testés lors de l'intervention",
            "pos": 420,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "essai_dm",
            "label": "Déclencheurs manuels OK",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Essai des déclencheurs manuels (DM)",
            "pos": 430,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "essai_baas",
            "label": "BAAS - Diffuseurs sonores OK",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Blocs Autonomes d'Alarme Sonore",
            "pos": 440,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "essai_das",
            "label": "DAS - Désenfumage OK",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Dispositifs Actionnés de Sécurité (désenfumage)",
            "pos": 450,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "essai_dcm",
            "label": "DCM - Portes coupe-feu OK",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Dispositifs de Commande Manuels (portes CF)",
            "pos": 460,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "essai_us_aes",
            "label": "US et AES - Tests OK",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Unités de Signalisation et Asservissements",
            "pos": 470,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "essai_transmission_alarme",
            "label": "Transmission alarme OK",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Transmission vers pompiers ou télésurveillance",
            "pos": 480,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "verif_batteries",
            "label": "Batteries alimentation secours OK",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "État et charge des batteries",
            "pos": 490,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "verif_signalisation",
            "label": "Signalisation visuelle OK",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Panneaux et voyants lumineux",
            "pos": 500,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        },
        {
            "name": "nettoyage_detecteurs",
            "label": "Nettoyage détecteurs effectué",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Nettoyage préventif des détecteurs",
            "pos": 510,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "0",
            "alwayseditable": 0
        },
        {
            "name": "anomalies_detectees",
            "label": "Anomalies détectées",
            "type": "text",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 0,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Description des défauts constatés",
            "pos": 600,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "operations_effectuees",
            "label": "Opérations effectuées",
            "type": "text",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 0,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Détail des interventions réalisées",
            "pos": 610,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "materiel_remplace",
            "label": "Matériel remplacé",
            "type": "text",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 0,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Liste du matériel remplacé (détecteurs, piles, etc.)",
            "pos": 620,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "preconisations",
            "label": "Préconisations",
            "type": "text",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 0,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Recommandations et travaux à prévoir",
            "pos": 630,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "conformite",
            "label": "État de conformité",
            "type": "select",
            "size": "",
            "required": 1,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": {
                "options": {
                    "bon_etat": "BON ÉTAT FONCTIONNEL",
                    "reserve_mineure": "RÉSERVES MINEURES",
                    "reserve_majeure": "RÉSERVES MAJEURES",
                    "non_conforme": "NON CONFORME",
                    "hors_service": "HORS SERVICE"
                }
            },
            "help": "Diagnostic final de l'installation",
            "pos": 700,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "bon_etat",
            "alwayseditable": 0
        },
        {
            "name": "date_prochaine_verif",
            "label": "Date prochaine vérification",
            "type": "date",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Date prochaine vérification (12 mois)",
            "pos": 710,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "date_prochaine_vre",
            "label": "Date prochaine VRE triennale",
            "type": "date",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Date prochaine Vérification Réglementaire en Exploitation (3 ans)",
            "pos": 720,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "technicien_nom",
            "label": "Nom du technicien",
            "type": "varchar",
            "size": "100",
            "required": 1,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Nom du technicien intervenant",
            "pos": 800,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "technicien_qualification",
            "label": "Qualification technicien",
            "type": "varchar",
            "size": "100",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Certification APSAD ou équivalent",
            "pos": 810,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "organisme",
            "label": "Organisme vérificateur",
            "type": "varchar",
            "size": "100",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Nom de l'organisme (pour VRE uniquement)",
            "pos": 820,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "",
            "alwayseditable": 0
        },
        {
            "name": "registre_securite_vise",
            "label": "Registre de sécurité visé",
            "type": "boolean",
            "size": "",
            "required": 0,
            "unique": 0,
            "visible": 1,
            "totalizable": 0,
            "printable": 1,
            "param": [],
            "help": "Visa du registre de sécurité effectué",
            "pos": 830,
            "enabled": 1,
            "perms": "",
            "langfile": "",
            "computed": "",
            "default": "1",
            "alwayseditable": 0
        }
    ],
    "pdf_layout": {
        "version": "1.0",
        "page": {
            "format": "A4",
            "orientation": "portrait",
            "margins": { "top": 20, "right": 15, "bottom": 20, "left": 15 },
            "font_family": "helvetica",
            "font_size": 10
        },
        "header": {
            "title": "Vérification SSI",
            "subtitle": "Conforme NF S 61-933 et MS 72-75",
            "logo_placeholder": "top-right",
            "show_page_number": true,
            "show_generated_date": true
        },
        "footer": {
            "text": "Document généré via schemas.cap-rel.fr",
            "legal_mentions": "Document à conserver dans le registre de sécurité de l'établissement"
        },
        "sections": [
            {
                "id": "identification",
                "title": "Identification de l'établissement",
                "layout": "two_columns",
                "fields": [
                    "ssi_etablissement",
                    "ssi_type_erp",
                    "ssi_categorie"
                ]
            },
            {
                "id": "intervention",
                "title": "Type d'intervention",
                "layout": "single_column",
                "fields": ["type_intervention"]
            },
            {
                "id": "verifications_documentaires",
                "title": "Vérifications documentaires",
                "layout": "checklist",
                "fields": [
                    "verif_dossier_identite",
                    "verif_autocontrole",
                    "verif_contrat_maintenance"
                ]
            },
            {
                "id": "essais_fonctionnels",
                "title": "Essais fonctionnels",
                "layout": "checklist",
                "fields": [
                    "essai_cmsi",
                    "essai_detecteurs",
                    "essai_dm",
                    "essai_baas",
                    "essai_das",
                    "essai_dcm",
                    "essai_us_aes",
                    "essai_transmission_alarme"
                ]
            },
            {
                "id": "mesures",
                "title": "Mesures",
                "layout": "inline",
                "fields": ["nb_detecteurs_testes"]
            },
            {
                "id": "verifications_equipements",
                "title": "Vérifications des équipements",
                "layout": "checklist",
                "fields": [
                    "verif_batteries",
                    "verif_signalisation",
                    "nettoyage_detecteurs"
                ]
            },
            {
                "id": "observations",
                "title": "Observations et opérations",
                "layout": "full_width",
                "fields": [
                    "anomalies_detectees",
                    "operations_effectuees",
                    "materiel_remplace",
                    "preconisations"
                ]
            },
            {
                "id": "conclusion",
                "title": "Conclusion de l'intervention",
                "layout": "highlight_box",
                "fields": [
                    "conformite",
                    "date_prochaine_verif",
                    "date_prochaine_vre"
                ]
            },
            {
                "id": "signatures",
                "title": "Validation",
                "layout": "signature_block",
                "fields": [
                    "technicien_nom",
                    "technicien_qualification",
                    "organisme",
                    "registre_securite_vise"
                ],
                "signature_boxes": [
                    { "label": "Signature technicien", "for_field": "technicien_nom" },
                    { "label": "Signature exploitant", "for_field": null }
                ]
            }
        ],
        "field_render": {
            "ssi_etablissement": { "style": "bold" },
            "conformite": {
                "style": "highlight",
                "color_by_value": {
                    "bon_etat": "#1f8a1f",
                    "reserve_mineure": "#e69500",
                    "reserve_majeure": "#d95500",
                    "non_conforme": "#c00000",
                    "hors_service": "#660000"
                }
            },
            "anomalies_detectees": { "min_height": 25, "show_if_empty": false },
            "operations_effectuees": { "min_height": 25, "show_if_empty": false },
            "materiel_remplace": { "min_height": 20, "show_if_empty": false },
            "preconisations": { "min_height": 20, "show_if_empty": false }
        }
    }
}