    "uuid": "82a4373907b2693a0c0726b3b7bbd35d",
    "elementtype": "fichinter",
    "schema_kind": "intervention",
    "title": "Fiche d'intervention - Vérification métrologique banc de freins",
    "description": "Vérification métrologique d'un banc de freins de garage (rouleaux, plaque, mixte), conformité contrôle technique et étalonnage des cellules de force.",
    "export_date": "2026-05-26 10:00:00",
    "dolibarr_version": "18.0.0",
    "extrafields": [
        {"name": "frn_etablissement", "label": "Établissement", "type": "varchar", "size": "200", "required": 1, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Raison sociale et adresse du garage / centre CT", "pos": 100, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0},
        {"name": "frn_site", "label": "Site", "type": "varchar", "size": "150", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Nom du site / agence", "pos": 105, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0},
        {"name": "frn_atelier", "label": "Atelier / travée", "type": "varchar", "size": "100", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Identification de l'atelier ou piste CT", "pos": 110, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0},
        {"name": "frn_identifiant_equipement", "label": "Identifiant équipement", "type": "varchar", "size": "50", "required": 1, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Numéro d'inventaire du banc de freins", "pos": 115, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0},
        {"name": "frn_marque_modele", "label": "Marque / modèle", "type": "varchar", "size": "150", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Constructeur et référence du banc", "pos": 120, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0},
        {"name": "frn_referent", "label": "Référent atelier", "type": "varchar", "size": "100", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Responsable du banc", "pos": 125, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0},
        {"name": "frn_type_banc", "label": "Type de banc", "type": "select", "size": "", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": {"options": {"rouleaux": "À rouleaux", "plaque": "À plaque (décélération)", "mixte": "Mixte rouleaux + plaque", "remorque": "Banc remorque / portable"}}, "help": "Technologie du banc contrôlé", "pos": 130, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "rouleaux", "alwayseditable": 0},
        {"name": "frn_type_intervention", "label": "Type d'intervention", "type": "select", "size": "", "required": 1, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": {"options": {"verification_metrologique": "Vérification métrologique périodique", "etalonnage_initial": "Étalonnage initial (mise en service)", "verification_apres_reparation": "Vérification après réparation", "controle_homologation_ct": "Contrôle d'homologation contrôle technique"}}, "help": "Nature de l'intervention", "pos": 200, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "verification_metrologique", "alwayseditable": 0},
        {"name": "frn_temperature_atelier", "label": "Température atelier (°C)", "type": "double", "size": "4,1", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Température ambiante au moment du contrôle", "pos": 205, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0},
        {"name": "frn_rouleaux_etat", "label": "État des rouleaux", "type": "select", "size": "", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": {"options": {"bon": "Bon état", "usure_normale": "Usure normale", "lisse": "Lissés, à remplacer"}}, "help": "Revêtement et adhérence", "pos": 300, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "bon", "alwayseditable": 0},
        {"name": "frn_rotation_rouleaux_ok", "label": "Rotation rouleaux conforme", "type": "boolean", "size": "", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Vitesse stable et synchronisation gauche/droite", "pos": 305, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "1", "alwayseditable": 0},
        {"name": "frn_palpeur_protections", "label": "Palpeurs et protections OK", "type": "boolean", "size": "", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Système de détection véhicule sur banc", "pos": 310, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "1", "alwayseditable": 0},
        {"name": "frn_etalonnage_cellules_force", "label": "Étalonnage cellules de force", "type": "boolean", "size": "", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Étalonnage selon procédure constructeur", "pos": 315, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "1", "alwayseditable": 0},
        {"name": "frn_masse_etalon_kg", "label": "Masse étalon utilisée (kg)", "type": "double", "size": "6,2", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Masse de référence appliquée", "pos": 320, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0},
        {"name": "frn_masse_etalon_certificat", "label": "Certificat de la masse étalon", "type": "varchar", "size": "100", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Référence du certificat d'étalonnage de la masse", "pos": 325, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0},
        {"name": "frn_ecart_max_force_pct", "label": "Écart maximal force (%)", "type": "double", "size": "5,2", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Écart sur mesure de force après étalonnage", "pos": 330, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0},
        {"name": "frn_ecart_max_deceleration_pct", "label": "Écart maximal décélération (%)", "type": "double", "size": "5,2", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Écart sur décélération mesurée (banc plaque)", "pos": 335, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0},
        {"name": "frn_asymetrie_droite_gauche", "label": "Asymétrie gauche/droite (%)", "type": "double", "size": "5,2", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Écart d'asymétrie résiduelle banc", "pos": 340, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0},
        {"name": "frn_pesee_essieu_verifiee", "label": "Pesée d'essieu vérifiée", "type": "boolean", "size": "", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Fonction pesée essieu calibrée (si présente)", "pos": 345, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "1", "alwayseditable": 0},
        {"name": "frn_tolerance_constructeur_respectee", "label": "Tolérance constructeur respectée", "type": "boolean", "size": "", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Tous les écarts dans la tolérance du fabricant", "pos": 350, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "1", "alwayseditable": 0},
        {"name": "frn_conformite_controle_technique", "label": "Conformité contrôle technique", "type": "boolean", "size": "", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Banc conforme à l'usage en contrôle technique périodique", "pos": 355, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "1", "alwayseditable": 0},
        {"name": "frn_homologation_ct_validee", "label": "Homologation CT validée", "type": "boolean", "size": "", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Approbation OTC / UTAC valide à ce jour", "pos": 360, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "1", "alwayseditable": 0},
        {"name": "frn_certificat_cofrac", "label": "Certificat COFRAC fourni", "type": "boolean", "size": "", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Certificat d'étalonnage COFRAC remis", "pos": 365, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "1", "alwayseditable": 0},
        {"name": "frn_certificat_numero", "label": "Numéro de certificat", "type": "varchar", "size": "100", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Référence du certificat d'étalonnage", "pos": 370, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0},
        {"name": "anomalies_constatees", "label": "Anomalies constatées", "type": "text", "size": "", "required": 0, "unique": 0, "visible": 0, "totalizable": 0, "printable": 1, "param": [], "help": "Description des défauts relevés", "pos": 500, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0},
        {"name": "mesures_correctives", "label": "Mesures correctives", "type": "text", "size": "", "required": 0, "unique": 0, "visible": 0, "totalizable": 0, "printable": 1, "param": [], "help": "Actions réalisées ou recommandées", "pos": 510, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0},
        {"name": "conclusion", "label": "Conclusion", "type": "select", "size": "", "required": 1, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": {"options": {"apte": "APTE - Conforme", "apte_reserve": "APTE avec réserves", "inapte": "INAPTE - Banc à immobiliser"}}, "help": "Résultat de la vérification métrologique", "pos": 600, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "apte", "alwayseditable": 0},
        {"name": "date_prochaine_verif", "label": "Date prochaine vérification", "type": "date", "size": "", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Périodicité annuelle ou biennale selon usage", "pos": 610, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0},
        {"name": "technicien_nom", "label": "Nom du technicien", "type": "varchar", "size": "100", "required": 1, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Intervenant qualifié", "pos": 700, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0},
        {"name": "qualification", "label": "Organisme et qualification", "type": "varchar", "size": "150", "required": 0, "unique": 0, "visible": 1, "totalizable": 0, "printable": 1, "param": [], "help": "Organisme de vérification, agrément, n° accréditation COFRAC", "pos": 710, "enabled": 1, "perms": "", "langfile": "", "computed": "", "default": "", "alwayseditable": 0}
    ],
    "pdf_layout": {
        "version": "1.0",
        "page": {"format": "A4", "orientation": "portrait", "margins": {"top": 20, "right": 15, "bottom": 20, "left": 15}, "font_family": "helvetica", "font_size": 10},
        "header": {"title": "Fiche de vérification métrologique banc de freins", "subtitle": "Étalonnage cellules de force et conformité contrôle technique", "logo_placeholder": "top-right", "show_page_number": true, "show_generated_date": true},
        "footer": {"text": "Document généré via schemas.cap-rel.fr", "legal_mentions": "Document à conserver pour traçabilité métrologique du banc"},
        "sections": [
            {"id": "identification", "title": "Identification du banc", "layout": "two_columns", "fields": ["frn_etablissement", "frn_site", "frn_atelier", "frn_identifiant_equipement", "frn_marque_modele", "frn_referent", "frn_type_banc"]},
            {"id": "intervention", "title": "Intervention et contexte", "layout": "two_columns", "fields": ["frn_type_intervention", "frn_temperature_atelier"]},
            {"id": "mecanique", "title": "Vérification mécanique", "layout": "two_columns", "fields": ["frn_rouleaux_etat", "frn_rotation_rouleaux_ok", "frn_palpeur_protections"]},
            {"id": "etalonnage", "title": "Étalonnage cellules et étalons", "layout": "two_columns", "fields": ["frn_etalonnage_cellules_force", "frn_masse_etalon_kg", "frn_masse_etalon_certificat"]},
            {"id": "ecarts", "title": "Écarts mesurés", "layout": "two_columns", "fields": ["frn_ecart_max_force_pct", "frn_ecart_max_deceleration_pct", "frn_asymetrie_droite_gauche", "frn_pesee_essieu_verifiee", "frn_tolerance_constructeur_respectee"]},
            {"id": "homologation", "title": "Conformité contrôle technique", "layout": "two_columns", "fields": ["frn_conformite_controle_technique", "frn_homologation_ct_validee", "frn_certificat_cofrac", "frn_certificat_numero"]},
            {"id": "observations", "title": "Anomalies et mesures correctives", "layout": "full_width", "fields": ["anomalies_constatees", "mesures_correctives"]},
            {"id": "conclusion", "title": "Conclusion de la vérification", "layout": "highlight_box", "fields": ["conclusion", "date_prochaine_verif"]},
            {"id": "signatures", "title": "Technicien et organisme", "layout": "signature_block", "fields": ["technicien_nom", "qualification"], "signature_boxes": [{"label": "Signature technicien", "for_field": "technicien_nom"}, {"label": "Signature exploitant", "for_field": null}]}
        ],
        "field_render": {
            "frn_etablissement": {"style": "bold"},
            "frn_identifiant_equipement": {"style": "bold", "frame": true},
            "conclusion": {"style": "highlight", "color_by_value": {"apte": "#1f8a1f", "apte_reserve": "#e69500", "inapte": "#c00000"}},
            "anomalies_constatees": {"min_height": 30, "show_if_empty": false},
            "mesures_correctives": {"min_height": 30, "show_if_empty": false},
            "frn_temperature_atelier": {"suffix": " °C"},
            "frn_masse_etalon_kg": {"suffix": " kg"},
            "frn_ecart_max_force_pct": {"suffix": " %"},
            "frn_ecart_max_deceleration_pct": {"suffix": " %"},
            "frn_asymetrie_droite_gauche": {"suffix": " %"}
        }
    }
}